December 2005 Issue In my October 2005 column about return loss, I commented: “An open circuit, short circuit or pure reactance terminating a transmission line are incapable of absorbing power from a forward, or incident wave. Thus, all incident current and voltage are reflected back toward the source.” It’s sometimes difficult to understand why this happens. Intuition suggests that a short at the end of the line will short-circuit the RF to ground, and an open circuit will radiate the RF into the air. But the RF really is reflected back toward the source in both cases. Grab a strong cup of coffee and read on to see why. For reference, much of the following explanation is paraphrased or excerpted from information in the books Reflections by M. Walter Maxwell, published by the American Radio Relay League; and Handbook of Coaxial Microwave Measurements, originally published by GenRad and reprinted by Gilbert Engineering (now Corning-Gilbert). Theory Transmission line theory tells us that the characteristic impedance Zc of a transmission line is defined as the ratio of voltage V to current I in a traveling wave: Zc (ohms) = V/I. For this discussion, assume the transmission line is lossless; things get really messy when attenuation is factored in the discussion. I’ll use “+” and “-” to designate incident (forward) and reflected (rearward) traveling waves. Imagine an incident wave leaving a signal source—say, the output of an amplifier, tap or perhaps the upstream output of a cable modem. As the incident wave leaves the source, it “sees” the characteristic impedance Zc of the line as a resistive load. The incident wave is an electromagnetic signal, so half of its energy is in the electric field (because of voltage), and half is in the magnetic field (because of current). The incident voltage V+ and current I+, which are constant along the transmission line, are in phase because Zc is resistive. As the incident wave travels along the transmission line, the ratio V+/I+ in the line equals the line’s characteristic impedance Zc. So far, so good. Shift your thoughts for a moment to the load or termination at the end of the transmission line. The ratio of total voltage to total current at the load equals the terminating impedance: Vt/It = Zt. If the incident wave is the only wave on the transmission line, then Vt = V+ and It = I+. Under these conditions, the load impedance Zt and transmission line impedance Zc are equal, and all incident power is absorbed by the load. Open circuit What happens if the end of the transmission line is an open circuit (Zt = infinity)? We know that there is no current in an open circuit, so the magnetic field at the open circuit collapses. The collapsing magnetic field creates an electric field with the same energy as the original magnetic field. The new electric field adds in phase with the original electric field, making the voltage at the open circuit twice the voltage of the incident wave. This represents the development of a standing wave—current is minimum, and voltage maximum. (Remember, the incident current and voltage were constant along the line until now.) The higher voltage at the open circuit and its electric field causes a reflected voltage wave V- to start traveling back toward the source. The new reflected wave is the same magnitude as the original incident wave (no energy was absorbed by the open circuit), so reflection coefficient Gamma = V-/V+ = 1. The motion of the new reflected electric field results in a new magnetic field whose phase is opposite that of the original magnetic field. The new magnetic field’s motion causes current to increase to the same magnitude as the original, so we have a reflected current wave I- with the opposite polarity and traveling in the opposite direction of the incident current I+. If we look at just the reflected wave, V-/I- = -Zc. The minus sign in front of Zc simply indicates that we’re dealing with a reflected wave traveling back toward the source. The total voltage or current at the load at any given point in time is the sum of voltages or currents of the incident and reflected waves: V = V+ + V- and I = I+ + I-. We know the reflected voltage is in phase with the incident voltage because the sum of the two at the open circuit load is double the original incident voltage—they add because they are in phase. The reflected current is out of phase with the incident current because the sum of the two is zero at the open circuit—they cancel because they are out of phase. Short circuit OK, so what happens if the end of the transmission line is a short circuit (Zt = 0)? The general mechanism for the creation of a reflection is the same as for an open circuit, but the electric and magnetic field actions and reflection polarities are reversed. The sum of incident and reflected voltage waves is zero at the short circuit load—they cancel because they are out of phase. The sum of incident and reflected current at the short circuit load is double the original incident value—they add because they’re in phase. In other words, with a short circuit load, the reflected voltage V- is out of phase with the incident voltage V+, and the reflected current I- is in phase with the incident current I+. When Zc is not equal to Zt—that is, when an impedance mismatch exists between the line and load—a reflection occurs. The reflected and incident waves interact to produce a standing wave. The standing wave’s distribution of voltage and current is a result of the superposition of the two traveling waves moving in opposite directions. Unlike the constant relationship V+/I+ in the incident traveling wave, the ratio of total voltage to total current in a standing wave is not a constant but varies from point to point along the transmission line. This shows up as the familiar “standing wave” on a sweep display. Ron Hranac is a technical leader, Broadband Network Engineering, for Cisco Systems and senior technology editor for Communications Technology. Reach him at [email protected].

The Daily

Subscribe

AT&T Hitting All Marks With Fiber, Fixed Wireless

AT&T is buzzing when it comes to the continued success of its broadband product portfolio, scoring 252,000 AT&T Fiber net adds in 1Q24.

Read the Full Issue
The Skinny is delivered on Tuesday and focuses on the cable profession. You'll stay in the know on the headlines, topics and special issues you value most. Sign Up

Calendar

Apr 25
2024 Cablefax 100 Awards Magazine Release: April 25, 2024
Jun 13
2024 American Broadband Congress Conference Registration is Open!
Jun 26
2024 FAXIES Awards Nominations Are Open!
Full Calendar

Jobs

Seeking an INDUSTRY JOB?
VIEW JOBS

Hiring? In conjunction with our sister brand, Cynopsis, we are offering hiring managers a deep pool of media-savvy, skilled candidates at a range of experience levels and sectors, The result will be an even more robust industry job board, to help both employers and job seekers.

Contact Rob Hudgins, [email protected], for more information.